Panic lock with
two cylinder perforations Passage function D for radiation protection doors
Nr. 1018 PZ
Standard version
Information
Special executions
Special version on request Function from the inside: The door has a lever handle on the inside. Pressing the lever handle retracts the latch and the pre-locked bolt. The door can be opened. Function from the outside: The door has a lever handle on the outside. The latch can be retracted using the lever handle. The door is not yet secured by pulling it to from the outside. To secure the door, it is necessary to lock it with the key. To open the door, the key must be used to unlock the door and the latch retracted by actuating the lever handle.
Standard version
Mandrel dimension | Forend | Lock case | Latch | Bolt | Followers | Panic device | Locking type abbreviation | Forend dimensions |
65/110 mm | 20, 24 mm stainless steel |
closed, galvanised |
Nickel-plated steel | Nickel-plated steel | 9 mm, both fully functional |
for 110 mm | PZ, RZ | 20, 24 |
Locking types | available mandrel dimensions | ||||
|
40/80, 50/90, 65/100, 65/110 and 65/120 mm |