Combination NM 22
Normal function manual locking of the inactive leaf
Nr. NM 22
Special executions
Functional description for inactive leaf: The inactive leaf cannot be unlocked until the active leaf has been opened using the door lever handle. Locking is performed manually after the door has been brought into the locking position and the shoot bolt rods have been pushed out of the door leaf into the door frame (top) and floor locking recess (bottom) by actuating the fitting. Active leaf: Inside: The active leaf can only be locked after the inactive leaf has been completely locked. It can be locked and unlocked from the inside with the key. In addition to the bolt, a shoot bolt rod is actuated at the top and bottom. When it is unlocked, the latch can be retracted with the door lever handle. Outside: There is a fixed knob on the outside of the active leaf. The active leaf can be locked and unlocked from the outside. Moreover, the latch can be retracted with the key via the key-operated latch.